Compare Designs

Others Use WALL Posts as Columns

Independent Column Supports are Better

Using the wall post as a column is not a new or innovative design. National Partitions invented it years ago. We eliminated the design for a number of reasons.

Others: Lost Flexibility

The design restricts the nonprogressive feature or access of individual panels.
By placing weight on the post, removing the posts on either side of a panel to access it was very difficult and required temporary column supports.

National Partitions design is more flexible and allows easy access without restriction because the structural steel is independent from the post system.

Others: Inefficient Design

Another issue with this design was that in order for all components to be universal and easy for installation, all of the posts needed to be designed the same. This meant that the posts that were not needed to carry any loads were unnecessarily designed heavier and more expensive. Efficient designs are
more cost effective. Therefore we do not build in features that are not always needed.

National Partitions design is more efficient. Only the components that are required to carry a load are engineered that way... and all of our components are universal.

Others: Lower Capacity
Posts that carry loads have lower capacities and more restrictions than independent columns. In this design there is no anchoring of the post to the foundation and there is no bolting of a beam to the post. For safe designs this greatly reduces the load capacity of the post and also the allowable building spans. National Partitions independent structural insert design has a higher load capacity and allows for wider building spans.

National Partitions structural elements have higher capacities. We can clear span over 60 feet and can design loads to over 125psf.

 

Others: Not always Code Compliant

There are also building code issues to consider. In many situations, this design must have an hourly fire rating. That is not possible if the design is aluminum (it melts). For those that are using steel posts it is not possible because their post allows heat to transfer to the other side. Either system would not pass the ASTM E119 fire endurance test that would be required.

National Partitions design never uses aluminum as a structural element and our designs are code compliant.

 

National Partitions uses independent structural steel elements and columns that are safe, efficient, and flexible...

 