IBC Chapter Ten - Means of Egress

1013.3 Common path of egress travel

 

Code Excerpt:

1013.3 Common path of egress travel

In occupancies other than Groups H-1, H-2 and H-3, the common path of egress travel shall not exceed 75 feet (22 860 mm). In occupancies in Groups H-1, H-2, and H-3, the common path of egress travel shall not exceed 25 feet (7620 mm).

Exceptions:

The length of a common path of egress travel in an occupancy in Groups B, F and S shall not be more than 100 feet (30 480 mm), provided that the building is equipped throughout with an automatic sprinkler system installed with accordance with section 903.3.1.1

Where a tenant space in an occupancy in Groups B, S and U has an occupant load of not more than 30, the length of a common path of egress travel shall not be more than 100 feet (30 480 mm).

The length of a common path of egress travel in occupancy in Groups I-3 shall not be more than 100 feet (30 480mm).

---------- TOP ----------